INSTALLATION

3-6

Manual 0-4640

3

C. Installing Optional Two-Stage Air Filter Kit

This optional two-stage air line filter is also for use on compressed air shop systems. Filter removes moisture and contami-
nants to at least 5 microns.

Connect the air supply as follows:

a. Attach the Two Stage Filter bracket to the back of the power supply per instructions supplied with the

filter assembly.

NOTE

For a secure seal, apply thread sealant to the fitting threads according to manufacturer's instructions. Do Not use
Teflon tape as a thread sealer as small particles of the tape may break off and block the small air passages in the torch.

b. Connect the two stage filter outlet hose to the inlet port of the Regulator / Filter Assembly.

c. Use only Synflex or equivalent grade hose. Use customer-supplied fittings to connect the air line to the Filter. A 1/4

NPT to 1/4" hose barbed fitting is shown as an example.

Art # A-03004

Regulator/Filter
Assembly

Hose

Clamp

1/4 NPT

Hose Fitting

1/4" (6 mm) Gas

Supply Hose)

2-Stage Filter
Inlet Port (IN)

Outlet Port

(OUT)

Regulator Inlet Port

Two Stage

Filter

Assembly

Optional Two-Stage Filter Installation