Section 2: introduction & description, 01 scope of manual, 02 general description – Tweco Merlin 6000GST Master PS User Manual

Page 15

Advertising
background image

Manual 0-2652

2-1

INTRODUCTION & DESCRIPTION

SECTION 2:

INTRODUCTION &

DESCRIPTION

2.01 Scope of Manual

This manual contains descriptions, operating instructions and
basic maintenance procedures for the Merlin 6000GST Plasma
Cutting Master Power Supply. Service of this equipment is
restricted to Thermal Dynamics trained personnel; unqualified
personnel are strictly cautioned against attempting repairs or
adjustments not covered in this manual, at the risk of voiding
the Warranty.

Read this manual thoroughly. A complete understanding of the
characteristics and capabilities of this equipment will assure
the dependable operation for which it was designed.

NOTE

This Manual may include references to the Power
Supply revision letter(s). There are old style and
new style data tags that may be encountered. The
old style data tag has the revision letter(s) at the
end of the serial number. The new style data tag
has the revision letter(s) in an area marked 'Rev'.

2.02 General Description

The Master Power Supply contains all operator controls,
electrical and gas inputs and outputs, and the torch leads
receptacle. A Slave Power Supply may be connected in
parallel to double the cutting capacity (amperage) of the Mas-
ter Power Supply. All signal inputs/outputs, gas, and torch
connections are still connected to the Master Power Supply
when the Slave Power Supply is used. The Slave Power Supply
has the same power circuits as the Master Power Supply. The
Master Power Supply can also be connected to a second Mas-
ter Power Supply and the equipment will automatically be con-
figured when the parallel cable is installed. Many options and
accessories can be added to further improve the versatility of
the system.

NOTES

Refer to the Merlin 6000 Plasma Cutting Slave
Power Supply Operating Manual 0-2570 for more
information on the Slave Power Supply.

The Merlin 6000 Slave Power Supply requires a
Merlin 6000GST Master Power Supply for proper
operation and torch connections.

A-01759

Figure 2-1 Power Supply

The 'Extra-Cool

TM

' Coolant supplied with the Power Sup-

ply can be used in ambient temperatures down to 10° F
(-12° C). If the ambient temperature will be below 10° F
(-12° C) use 'Ultra-Cool

TM

' Coolant. This coolant is for

areas where the ambient temperature drops to -27° F
(-33° C).

A typical system configuration will contain the following:

• One or two Power Supplies with Running Gear

• Gas Control Module (GCM6000)

• Arc Starter Box

• Maximizer 300 Machine Torch with Leads, Mount-

ing Assembly and Gas Control Assembly

• Torch Supply Leads

• Maximizer 300 Spare Parts Kit

• 25 ft (7.6 m) Work Cable and Ring Lug

• Standard Air Line Filter Assembly

• Optional High Pressure Regulators

NOTE

Refer to Section 2.05 for complete list of Power Sup-
ply Options and Accessories.