APPENDIX 1: INPUT WIRING REQUIREMENTS

In p u t

P o w er In p u t

C u r r en t

S u g g ested S iz es ( S ee N o te)

V o lt ag e

F r eq .

3- P h

3- P h

F u se (A m p s)

W ir e ( A W G )

W ir e ( C an ad a)

(V o lts)

(H z )

(kV A )

(A m p s)

3- P h

3- P h

3- P h

200

50/60

34

98

110

2

2

208

50/60

34

95

110

2

2

220

50/60

34

89

100

2

4

230

50/60

34

85

100

4

4

380

50/60

34

51

60

6

8

415

50/60

34

47

60

8

8

460

50/60

34

42

50

8

8

506

50/60

34

40

45

8

8

575

50/60

34

34

40

8

10

Li ne V ol tages w i th S ugges ted C i rc ui t P rotec ti on and W i r e S i z es

B as ed on N ati onal E l ec tri c C ode and C anadi an E l ec tri c al C ode

NOTES

Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.

Cable size is de-rated based on the Duty Cycle of the equipment.

The suggested sizes are based on flexible power cable with power plug installations. For hard-wired installations
refer to local or national codes.

Cable conductor temperature used is 167° F (75° C).

An energy limiting fuse UL Class RK-1 (examples: BUSS LPS/LPN-RK or Gould-Shawmut AZK-A6K) should be
used to minimize damage to Plasma Cutting, Welding or power distribution equipment.

NEVER

use replaceable element fuses like UL Class H, or "one-time" fuses like UL Class K5.