APPENDIX 1: INPUT WIRING REQUIREMENTS
In p u t
P o w er In p u t
C u r r en t
S u g g ested S iz es ( S ee N o te)
V o lt ag e
F r eq .
3- P h
3- P h
F u se (A m p s)
W ir e ( A W G )
W ir e ( C an ad a)
(V o lts)
(H z )
(kV A )
(A m p s)
3- P h
3- P h
3- P h
200
50/60
34
98
110
2
2
208
50/60
34
95
110
2
2
220
50/60
34
89
100
2
4
230
50/60
34
85
100
4
4
380
50/60
34
51
60
6
8
415
50/60
34
47
60
8
8
460
50/60
34
42
50
8
8
506
50/60
34
40
45
8
8
575
50/60
34
34
40
8
10
Li ne V ol tages w i th S ugges ted C i rc ui t P rotec ti on and W i r e S i z es
B as ed on N ati onal E l ec tri c C ode and C anadi an E l ec tri c al C ode
NOTES
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
Cable size is de-rated based on the Duty Cycle of the equipment.
The suggested sizes are based on flexible power cable with power plug installations. For hard-wired installations
refer to local or national codes.
Cable conductor temperature used is 167° F (75° C).
An energy limiting fuse UL Class RK-1 (examples: BUSS LPS/LPN-RK or Gould-Shawmut AZK-A6K) should be
used to minimize damage to Plasma Cutting, Welding or power distribution equipment.
NEVER
use replaceable element fuses like UL Class H, or "one-time" fuses like UL Class K5.