Tweco Merlin 6000GST Master PS User Manual

Page 45

Advertising
background image

Manual 0-2652

4-7

OPERATION

NOTE

Auto Pilot Restart is factory set to be disabled.

Disabling Auto Pilot Restart improves parts life by
preventing extra pilot restarts at the end of a cut when
pilot is not needed. In some cases auto pilot restart
may be required when cutting over holes, wide kerfs,
expanded metal, etc.

When using oxygen (O

2

) plasma, Auto Pilot Restart

is not normally available but may be enabled if re-
quired (contact the the factory or authorized distribu-
tor for instructions).

For all other gases , Auto Pilot Restart is selected by
setting both SW1-1 and SW1-2 to '0' (off). With this
setting pilot will restart immediatly when the cutting
arc is lost, if torch remains activated.

NOTE

Either pole set to 1 (on) disables auto-restart func-
tion.

A u to -R e s tart

F u n c ti o n

SW 1-1

Po s itio n

SW 1-2

Po s itio n

En a b le d

0 (O f f)

0 (O f f)

D isa b le d

0 (O f f)

1 (O n )

D isa b le d

1 (O n )

0 (O f f)

D isa b le d *

1 (O n )

1 (O n )

* = F act o ry Se t ting

B. Delayed Restart Mode (SW2)

ON

OFF

1 2

SW2

A-00992

Logic PC Board

Figure 4-9 Delayed Restart Mode Switch SW2

Location

When the torch is first activated there is a delay
called"preflow" that allows plasma gas to flow be-
fore the pilot arc starts. For plasma gases other than
oxygen (O

2

), if the plasma is already flowing (still in

"postflow" from a previous operation) pilot starts im-
mediately without the delay. This may not always
be desirable.

To always go through "preflow", select Delayed Re-
start by setting SW2-1 & SW2-2 to '1' (on). When
oxygen (O

2

) plasma is selected, because there is no

"postflow" of plasma gas, Delayed Restart is auto-
matically activated no matter how SW2 is set.

NOTE

Either pole set to 1 (on) sets delayed auto-restart
function.

Delayed

Restart Mo d e

SW 2-1

Po sitio n

SW 2-2

Po sitio n

Normal *

0 (O ff)

0 (O ff)

Delayed

0 (O ff)

1 (O n)

Delayed

1 (O n)

0 (O ff)

Delayed

1 (O n)

1 (O n)

* = F actory Setting

Advertising