Tweco Merlin 6000GST Master PS User Manual

Page 46

Advertising
background image

OPERATION

4-8

Manual 0-2652

C. Gas Pre-Flow Delay (SW3)

ON

OFF

1 2

SW3

A-00993

Logic PC Board

Figure 4-10 Gas Pre-Flow Delay Switch SW3

Location

The pre-flow delay allows time for gases to flow to
the torch when the torch is activated. Pre-flow is im-
mediately followed by pilot arc initiation. Pre-flow
is factory-set at 0.5 seconds, but can be reset to 2, 3,
or 4 seconds as desired. Extended torch leads may
require longer pre-flow durations.

Pre-F lo w T ime

(Seco n d s)

SW 3-1

Po sitio n

SW 3-2

Po sitio n

0.5 *

0 (O ff)

0 (O ff)

2

0 (O ff)

1 (O n)

3

1 (O n)

0 (O ff)

4

1 (O n)

1 (O n)

* = F actory Setting

D. Gas Post-Flow Delay (SW4)

ON

OFF 1 2

SW4

A-00994

Logic PC Board

Figure 4-11 Gas Post-Flow Delay Switch SW4

Location

Post-flow delay allows gases to flow after the main
cutting arc is interrupted. Post-flow is factory-set at
10 seconds, but can be reset to 5, 20, or 40 seconds.

P o s t-F l o w T i m e

(S e c o n d s )

S W 4 -1

P o s i ti o n

S W 4 -2

P o s i ti o n

5

0 (O f f )

1 (O n )

1 0 *

0 (O f f )

0 (O f f )

2 0

1 (O n )

0 (O f f )

4 0

1 (O n )

1 (O n )

* = F a ct o ry S e t t in g

Advertising