04 removing skid, 05 input power connections – Tweco Merlin 6000GST Master PS User Manual

Page 22

Advertising
background image

INSTALLATION PROCEDURES

3-2

Manual 0-2652

D. Unpacking Procedure

1. Unpack each item and remove all packing material.

2. Locate the packing list(s) and use the list to identify

and account for each item.

3. Inspect each item for possible shipping damage. If

damage is evident, contact your distributor before pro-
ceeding with installation.

3.04 Removing Skid

The Power Supply is mounted on the skid with two brackets.
Remove the Power Supply from the skid as follows:

1. Remove the six bolts connecting the brackets to the base of

the Power Supply.

A-01760

Three Bolts

(Each Side)

Shipping Brackets

Shipping Pallet

Figure 3-1 Skid Removal From Power Supply

2. Roll the Power Supply off the skid backwards (rear wheels

first).

3.05 Input Power Connections

The Power Supply accepts input voltages from 200V to 575V, 50
or 60 Hz, three-phase power. Every Power Supply is factory
wired for 380-460V input. For any other input voltage, the Power
Supply must be reset.

NOTE

Refer to Section 3.07, Voltage Selection.

A. Electrical Connections

The power source must conform to local electric code and the
recommended circuit protection and wiring requirements shown
in Appendix 1.

B. Input Voltage Selection

Every Power Supply is factory-wired for 380-460V three-phase
input. For any other input voltage, the Power Supply must be
changed using the procedures in Section 3.07.

Advertising