13 master/slave parallel cable connection – Tweco Merlin 6000GST Master PS User Manual
Page 33
Manual 0-2652
3-13
INSTALLATION PROCEDURES
TB2
Connection
Description
1
One Side of Enable Signal (Common)
2
Other Side of Enable Signal (+15 vdc)
3
One Side of START(Low)/STOP (High) Signal
(+15 vdc)
4
Other Side of START (Low)/STOP (High) Signal
(Common)
5
Not Used
6
Not Used
7
One Side of Pilot Sensing Relay (PSR) - Dry
Contacts
8
Other Side of Pilot Sensing Relay (PSR) - Dry
Contacts
9
One Side of OK-To-Move Signal (Refer to
Section 4.06)
10
Other Side of OK-To-Move Signal (Refer to
Section 4.06)
NOTES
Connections to TB2 positions 1 through 4 are ac-
tivated with a switch or contact closure.
If Remote Control is not used the Enable Signal
circuit must be closed.
Connections TB2-7 and TB2-8 are normally open
(NO) contacts.
Connections TB2-9 and TB2-10 are selectable for
normally open (NO) contacts or 24 VAC.
e. Secure the CNC cable by tightening the two screws
on the strain relief.
f. Reinstall the Left Side Panel.
C. Optional SC-10 or SC11 Standoff Control
Cable
For mechanized systems, the Standoff Control automati-
cally finds height and maintains torch standoff with a high
speed torch lifter motor. The unit consists of a remote
operator's control, torch lifter motor, and all cables re-
quired for installation. It is ordered and shipped sepa-
rately. Refer to the SC-10 or SC11 Standoff Control In-
struction Manual for more information.
Depending on the Standoff Control to be used connect the
cable per one of the following:
• Standoff Control SC10 used with the Remote Control
RC6010
Connect the internal ribbon cable to the Remote Con-
trol RC6010. Refer to the Standoff Control Instruction
Manual for more details.
• Standoff SC11 only
The standoff control remote cable connects to the re-
ceptacle marked REMOTE CONTROL (J15) on the rear
panel of the Power Supply.
A-01766
Cable From
Standoff Control
REMOTE
CONTROL J15
Connector
Figure 3-15 Standoff Control Interface Connection