Tweco Merlin 6000GST Master PS User Manual

Page 36

Advertising
background image

INSTALLATION PROCEDURES

3-16

Manual 0-2652

Master and Slave Power Supply pilot resistors are initially set
at the factory and may need to be adjusted to the customer's
input power (see Notes).

NOTES

The instructions in this Sub-Section apply to the
Master Power Supply only.

To adjust the Slave Power Supply pilot resistor,
refer to the Manual supplied with the Slave Power
Supply.

WARNING

Disconnect primary power at the source before as-
sembling or disassembling power supply, torch
parts, or torch and leads assemblies.

The pilot current consists of two parts:

1) Minimum or “background” level

2) Pulse or peak level

The background level has to be high enough that the pi-
lot will not sputter or go out, but not too high to cause
excessive wear of the torch consumables. Adding pulses
of current on top of the background current allows greater
arc transfer distance without increasing the torch part
wear. The amount of pilot current is determined by the
value of the pilot resistors and the open circuit voltage
which varies with the input line voltage. Both the Mas-
ter and the Slave Power Supplies should be adjusted the
same. Wire #99 tap sets the background level and wire
#150 tap sets the pulse level. Set the pilot background and
pulse levels as follows:

1. Remove the left and right side panels of the Master

Power Supply.

2. Locate and identify the pilot resistors (R16, R21 and

R22) which are on a bracket in front of the fan.

Wire

#96A

Pilot Resistor

R16

Clamp

Clamp

A-01853

Wire

#150

Pilot Resistor

R21

Pilot Resistor

R22

Wire

#74

Wire #99

Wire

#96

Temp

Switch

Figure 3-20 Location Of Pilot Resistors (Viewed From

The Front Of Power Supply)

3. Check the busbar configuration on the input terminal

board to determine which range the power transformer
is set for.

4. Measure the level of the AC line voltage being sup-

plied to the Power Supply.

5. To determine the recommended pilot resistor setting

use the following table as follows:

a. Locate the transformer voltage range (200-230V, 380-

460V or 500-575V)

b. Find the voltage that is nearest what was measured

above.