INSTALLATION PROCEDURES
3-4
Manual 0-2652
200, 208,
220, or 230
11
12
L3
13
15
14
6
7
L2
8
10
9
1
2
L1
3
5
4
380, 415,
or 460
11
12
L3
13
15
14
6
7
L2
8
10
9
1
2
L1
3
5
4
500, or 575
11
12
L3
13
15
14
6
7
L2
8
10
9
1
2
L1
3
5
4
Busbar Connections For Input Voltages
A-00904
Figure 3-4 Busbar Connections
If necessary, reposition the busbars to correspond to the
available line voltage.
3.07 Primary Power Cable
Connections
WARNING
Disconnect primary power at the source before con-
necting the primary power cable to the power sup-
ply.
The primary power cable must be supplied by the end
user and installed to the Power Supply assembly. Rec-
ommended cable sizes are specified in Appendix 1.
NOTE
Three-phase operation requires a 3-conductor
cable with ground.
1. Route the primary power cable through the strain relief
fitting in the rear panel of the Power Supply and tighten
strain relief screws.
Input Voltage
Terminal Board
L1
L2
L3
Primary Power
Cable
Strain Relief
Fitting
Ground
Connection
Busbars
A-01829
Figure 3-5 Input Voltage Connections
2. Connect the electrical ground wire to the ground lug
on the base of the unit.
WARNING
The electrical ground wire must be connected to
the ground lug in the base of the unit for proper
grounding.
3. Connect the three line leads to the input voltage
terminal board as follows:
• Line 1 to terminal L1.
• Line 2 to terminal L2.
• Line 3 to terminal L3.
4. Tighten all nuts.