08 work cable and ground connections, 07 primary power cable connections – Tweco Merlin 6000GST Master PS User Manual

Page 24

Advertising
background image

INSTALLATION PROCEDURES

3-4

Manual 0-2652

200, 208,

220, or 230

11

12

L3

13

15

14

6

7

L2

8

10

9

1

2

L1

3

5

4

380, 415,

or 460

11

12

L3

13

15

14

6

7

L2

8

10

9

1

2

L1

3

5

4

500, or 575

11

12

L3

13

15

14

6

7

L2

8

10

9

1

2

L1

3

5

4

Busbar Connections For Input Voltages

A-00904

Figure 3-4 Busbar Connections

If necessary, reposition the busbars to correspond to the
available line voltage.

3.07 Primary Power Cable

Connections

WARNING

Disconnect primary power at the source before con-
necting the primary power cable to the power sup-
ply.

The primary power cable must be supplied by the end
user and installed to the Power Supply assembly. Rec-
ommended cable sizes are specified in Appendix 1.

NOTE

Three-phase operation requires a 3-conductor
cable with ground.

1. Route the primary power cable through the strain relief

fitting in the rear panel of the Power Supply and tighten
strain relief screws.

Input Voltage

Terminal Board

L1

L2

L3

Primary Power

Cable

Strain Relief

Fitting

Ground

Connection

Busbars

A-01829

Figure 3-5 Input Voltage Connections

2. Connect the electrical ground wire to the ground lug

on the base of the unit.

WARNING

The electrical ground wire must be connected to
the ground lug in the base of the unit for proper
grounding.

3. Connect the three line leads to the input voltage

terminal board as follows:

• Line 1 to terminal L1.

• Line 2 to terminal L2.

• Line 3 to terminal L3.

4. Tighten all nuts.