03 specifications & design features – Tweco Merlin 6000GST Master PS User Manual

Page 16

Advertising
background image

INTRODUCTION & DESCRIPTION

2-2

Manual 0-2652

2.03 Specifications & Design

Features

The following apply to the Master Power Supply only:

1. Controls

ON/OFF Switch, Output Current Control, Arc Hour/
Counter Meters

2. Control Indicators

LED Indicators:

AC , TEMP, GAS, DC, PILOT, COOLANT PRES, and
COOLANT COND

3. Input Power

V o lt a g e

F re q u e n cy

P h a se A m p e ra g e

2 0 0

5 0 o r 6 0 H z

3

9 8

2 2 0

5 0 o r 6 0 H z

3

8 9

2 3 0

5 0 o r 6 0 H z

3

8 5

3 8 0

5 0 o r 6 0 H z

3

5 1

4 1 5

5 0 o r 6 0 H z

3

4 7

4 6 0

5 0 o r 6 0 H z

3

4 2

5 0 0

5 0 o r 6 0 H z

3

4 0

5 7 5

5 0 o r 6 0 H z

3

3 4

NOTE

Refer to Appendix 1 for recommended input wir-
ing size, current ratings, and circuit protection re-
quirements.

Amperage depends on input voltage (Refer to Ap-
pendix 1).

4. Output Power

Master Power Supply:

Continuously adjustable by potentiometer from 50
to 150 amps

With Slave Power Supply:

Continuously adjustable by potentiometer from
100 to 300 amps

5. Duty Cycle (see NOTE)

NOTE

The duty cycle will be reduced if the primary in-
put voltage (AC) is low or the DC voltage is higher
than shown in the chart.

Ambient

Temperature

104° F (40° C)

Duty Cycle

100%

Current

150 Amps

DC Voltage

140 vdc

Power Supply Duty Cycle

6. Pilot Modes

Auto-Restart, Pre-Flow Delay, "Recycle Required"

NOTE

Pilot modes 'Auto-Restart' and 'Recycle Required'
not recommended when using oxygen (0

2

) as

plasma gas.

7. CNC Signals

a. Power Supply

Enable, Start/Stop, OK-To-Move, Pilot Sensing Re-
lay (PSR)

b. Remote Control

Full CNC available with Remote Control

8. Coolant Pressure

Internal Coolant Pressure Gauge

Internal Service-adjustable

130 psi (8.8 bar) at zero flow

120 - 125 psi (8.2 - 8.5 bar) at 0.6 gpm (2.6 lpm)

9. Coolant Flow Rate

0.5 gpm (2.2 lpm) with 150 feet of total torch and torch
leads at 70°F (21°C)

NOTE

The flow rate varies with lead length, torch con-
figuration, ambient temperature, amperage level,
etc.

10. Cooling Capacity

4,000 to 10,000 BTU

NOTE

Maximum value based on “free flow” condition.

Advertising