06 voltage selection, 07 primary power cable connections – Tweco Merlin 6000GST Master PS User Manual

Page 23

Advertising
background image

Manual 0-2652

3-3

INSTALLATION PROCEDURES

C. Opening Power Supply Enclosure

The left side panel (viewed from the front) of the Power Supply
must be removed to make electrical connections and to select
the proper input voltage.

WARNING

Disconnect primary power at the source before
assembling or disassembling power supply, torch
parts, or torch and leads assemblies.

1. Remove the eight screws which secure the left side

panel (viewed from the front) to the Power Supply.

2. Loosen the two bottom screws in the slotted holes.

Left Side Panel

Screws

(10 Places)

A-01528

Figure 3-2 Opening Power Supply

3. Pull the top of the Left Side Panel out and then lift up to

remove the panel from the Power Supply.

3.06 Voltage Selection

The Power Supply can be wired to use input voltages from 200
- 575 VAC. Power Supply is factory-wired for 380-460 VAC,
three-phase input. Voltage selection is accomplished by switch-
ing busbar connections on the input voltage terminal board
inside the Power Supply.

1. Locate the input voltage terminal board on the left side

of the power supply.

Input Voltage

Terminal Board

L1

L2

L3

Busbars

A-01828

Extra Busbar

Storage Location

Figure 3-3 Input Voltage Terminal Board Location

NOTE

Extra busbars are attached (stored) to the top
side of the power transformer assembly.

2. Check the busbar configuration on the input voltage

terminal board . The busbar configuration must corre-
spond with the available line voltage per the following
figure and the label inside the unit:

Advertising