10 gas requirements, 11 gas applications, 10 gas requirements -5 2.11 gas applications -5 – Tweco 300 Ultra-Cut(March 2013) User Manual

Page 21: Ultra-cut 300

Advertising
background image

Manual No. 0-5134

2-5

SPECIFICATIONS

ULTRA-CUT 300

2.10 Gas Requirements

The customer will provide all gases and pressure regulators. Gases must be of high quality. Pressure regulators
shall be double stage and installed within 3 meters from the Gas Console.

Gas

Quality

Minimum Pressure

Flow

O

2

(Oxygen)

99.5% Purity

(Liquid recommended)

120 psi

8.3 bar / 827 kPa

200 scfh (5700 l/h)

N

2

(Nitrogen)

99.5% Purity

(Liquid recommended)

<1000 ppm O

2

, <32

ppm H

2

O)

120 psi

8.3 bar / 827 kPa

300 scfh (8496 l/h)

Compressed

or Bottled Air

Clean, Dry,

Free of Oil (see Note 1)

120 psi

8.3 bar / 827 kPa

450 scfh (12743 l/h)

H35 (Argon-Hydrogen)
H35 = 35% Hydrogen,

65% Argon

99.995% Purity

(gas

recommended)

120 psi

8.3 bar / 827 kPa

200 scfh (5664 l/h)

Ar (Argon)

99-995% Purity

(gas recommended)

80 psi

5.5 bar / 550 kPa

64 scfh (1800 l/h)

H

2

O (Water)

See Note 2

50 psi (3.5 bar)

10 gph (38 lph)

Ultra-Cut 300 Power Supply: Gas Pressures, Flows, and Quality Requirements

Note 2: The tap water source does not need to be deionized, but in water systems with extremely high
mineral content a water softener is recommended. Tap water with high levels of particulate matter must be
filtered.

Note 1: The air source must be adequately filtered to remove all oil or grease. Oil or grease
contamination from compressed or bottled air can cause fires in conjunction with oxygen.

For filtering, a coalescing filter able to filter to 0.01 microns should be placed as close as
possible to the gas inlets on the Gas Control Module.

2.11 Gas Applications

MATERIAL

OPERATION PREFLOW

PLASMA

SHIELD

PREFLOW

PLASMA

SHIELD

PREFLOW

PLASMA

SHIELD

Air

Air

Air

Air

Air

Air

N

2

N

2

H

2

0

N

2

N

2

H

2

0

Air

Air

Air

Air

Air

Air

N

2

N

2

H

2

0

N

2

N

2

H

2

0

Air

Air

Air

Air

Air

Air

N

2

N

2

H

2

0

N

2

N

2

H

2

0

85A Cut

Air

Air

Air

N

2

H

35

N

2

N

2

H

35

N

2

N

2

N

2

H

2

0

N

2

N

2

H

2

0

N

2

H

35

N

2

N

2

H

35

N

2

N

2

N

2

H

2

0

N

2

N

2

H

2

0

300A Cut

Air

O

2

Air

100A Cut

150A Cut

O

2

Air

Air

O

2

Air

50A Cut

O

2

Air

Air

70A Cut

O

2

Air

Air

O

2

O

2

Air

Air

MILD STEEL

STAINLESS STEEL

ALUMINUM

30A Cut

GAS TYPE

GAS TYPE

GAS TYPE

Advertising