OPERATION

4-22

Manual No. 0-5134

ULTRA-CUT 300

Code Message

Cause/Remedy

6-1

Valve open

Check for open connection; Replace valve.

6-2

DPC inlet Supply
pressure low

Raise plasma inlet pressure; check for DMC valve not open; restriction in gas
supply/hoses.

6-3

Outlet pressure too low Valve full open but pressure still too low. Leak in plasma hose to torch; Defective control

valve (V4); Defective pressure sensor (PS6); DPC Control PCB

6-4

Outlet pressure low

Tracking error. Leak in plasma hose to torch; Defective control valve (V4); Defective
pressure sensor (PS6); DPC Control PCB

6-5

Outlet pressure Too
high

Valve at minimum setting but pressure still too high. Restriction in plasma hose to torch;
torch or DPC manifold; Defective control valve (V4); Defective pressure sensor (PS6); DPC
Control PCB

6-6

Outlet pressure high

Tracking error. Restriction in plasma hose; torch or DPC manifold; Defective control valve
(V4); Defective pressure sensor (PS6); DPC Control PCB

7-1

Valve open

Check for open connection; Replace valve.

7-2

DPC inlet Supply
pressure low

Raise plasma inlet pressure; check for DMC valve not open; restriction in gas
supply/hoses.

7-3

Outlet pressure too low Valve full open but pressure still too low. Leak in plasma hose to torch; defective control

valve; defective pressure sensor (PS6); DPC Control PCB

7-4

Outlet pressure low

Tracking error. Leak in plasma hose to torch; defective control valve; defective pressure
sensor (PS6); DPC Control PCB

7-5

Outlet pressure Too
high

Valve at minimum setting but pressure still too high. Restriction in plasma hose, torch,
DPC manifold; defective control valve; defective pressure sensor (PS6); DPC Control PCB

7-6

Outlet pressure high

Tracking error. Restriction in plasma hose, torch, DPC manifold; defective control valve;
defective pressure sensor (PS6); DPC Control PCB

8-1

Valve open

Check for open connection; Replace valve.

8-2

DPC inlet Supply
pressure low

Raise plasma inlet pressure; check for DMC valve not open; restriction in gas
supply/hoses.

8-3

Outlet pressure too low Valve full open but pressure still too low. Leak in plasma hose to torch; defective control

valve; defective pressure sensor (PS5); DPC Control PCB

8-4

Outlet pressure low

Tracking error. Leak in plasma hose to torch; defective control valve; defective pressure
sensor (PS5); DPC Control PCB

8-5

Outlet pressure Too
high

Valve at minimum setting but pressure still too high. Restriction in plasma hose, torch,
DPC manifold; defective control valve; defective pressure sensor (PS5); DPC Control PCB

8-6

Outlet pressure high

Tracking error. Restriction in plasma hose, torch, DPC manifold; defective control valve;
defective pressure sensor (PS5); DPC Control PCB

9-1

Valve open

Check for open connection; Replace valve.

9-2

DPC inlet Supply
pressure low

Raise plasma inlet pressure; check for DMC valve not open; restriction in gas
supply/hoses.

9-3

Outlet flow too low

Valve full on but pressure still too low. Leak in shield hose to torch; Defective control valve
(V2); Defective pressure sensor (PS5) or flow sensor (FS-1) if equiped; DPC Control PCB

9-4

Outlet flow low

Tracking error, outlet pressure too low. Leak in shield hose to torc; Defective control valve
(V2). Defective pressure sensor (PS5) or flow sensor (FS-1) if equiped; DPC Control PCB

9-5

Outlet flow Too high

Valve set to minimum but valve outlet pressure still too high. Mineral build up or other
restriction in control valve (V2), DPC manifold, shield hose or torch; Defective control valve
(V2)/ Defective pressure sensor (PS5) or flow sensor (FS-1) if equiped; DPC Control PCB

9-6

Outlet flow high

Tracking error, outlet pressure too high. Mineral build up or other restriction in control
valve (V2), DPC manufold, shield hose or torch; Defective control valve (V2); Defective
pressure sensor (PS5) or flow sensor (FS-1) if equiped; DPC Control PCB

Group 9 - Shield H2O Proportional Valve (V2)

DPC Status Code Key

Group 6 - Plasma Low Proportional Valve (V4)

Group 7 - Pilot Proportional Valve (V3)

Group 8 - Shield Gas Proportional Valve (V1)