Ultra-cut 300 – Tweco 300 Ultra-Cut(March 2013) User Manual

Page 90

Advertising
background image

OPERATION

4-20

Manual No. 0-5134

ULTRA-CUT 300

Code

Message

Cause/Remedy

1-1

Plasma Disabled

Enable Plasma; Defective DMC Power Supply (E-Stop relay)

1-2

24 VDC fault

Check /replace DMC power supply fuse (F2); Replace DMC Power Supply; Replace DMC
control PCB

1-3

5 VDC fault

Check /replace DMC power supply; Replace DMC control PCB

1-4

No gas process selected

Select and send process from TSC 3000 or CNC;

1-5

DMC is locked

Process loading, wait until finished

1-6

Gas not Purged

DPC fault prevented purge from occuring, see DPC fault status

2-1

DPC Acknowledge error

Check DMC to DPC fiber optic cable and connections; Dirty or defective fiber-optic;DPC
power supply, fuse or Control PCB. DMC Control PCB

2-2

DPC Bus off error

Check DMC to DPC fiber optic cable and connections; Dirty or defective fiber-optic;DPC
power supply, fuse or Control PCB. DMC Control PCB.

2-3

Reserved

No information available; Contact customer service

3-1

CCM Acknowledge error

Check DMC to CCM fiber optic cable and connections; Dirty or defective fiber-optic;
Replace DMC Control PCB; Replace CCM.

3-2

CCM Bus off error

Check DMC to CCM fiber optic cable and connections; Dirty or defective fiber-optic;
Replace DMC Control PCB; Replace CCM.

3-3

Reserved

No information available; Contact customer service

4-1

CCM Connection loss

Loss of communication with either DPC or DMC; check for dirty or defective fiber optic
to either DPC or CCM; See DPC and CCM status codes

4-2

CCM Timeout

Loss of communication with either DPC or DMC, check for dirty or defective fiber-optic
to either DPC or CCM. See DPC and CCM status codes.

4-3

DPC Timeout

Loss of communication with DPC, check for dirty or defective fiber-optic to DPC. See
DPC status code.

4-4

DPC error

Loss of communication with DPC, check for dirty or defective fiber-optic to DPC. See
DPC status code.

4-5

Reserved

No information available; Contact customer service

4-6

Reserved

No information available; Contact customer service

5-1

Sol 1 – H35 Plasma

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-2

Sol 2 – Oxygen Plasma

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-3

Sol 3 – Air Plasma

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-4

Sol 4 – Nitrogen Plasma

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-5

Sol 5 – Aux Plasma

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-6

Sol 6 – Oxygen Shield

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-7

Sol 7 – Air Shield

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-8

Sol 8 – Nitrogen Shield

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-9

Sol 9 – H

2

O Shield

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-10

Sol 10 – Oxygen Preflow

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-11

Sol 11 – Air Preflow

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-12

Sol 12 – Nitrogen Preflow

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-13

Sol 13 – Argon Marking

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-14

Sol 14 – Air Marking

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

5-15

Sol 15 – Nitrogen Marking

Replace solenoid; Shorted wire harness; Defective DMC Control PCB

Group 4 - Gas Controller Status and Protocal Errors

Group 5 - Shorted Solenoid Faults

* Communication faults shown on the DMC can be caused by the device on the other end of the communication line. Before
assuming the DMC is at fault see if either the CCM or the DPC are showing any codes that might indicate they are at fault instead.

DMC Status Code Key

Group 1 - DMC

Group 2 - DPC Communication Port *

Group 3 - CCM Communication Port *