06 functional block diagrams, 07 transporting methods, Arcmaster 200 ac/dc – Tweco 200 ACDC Arcmaster(April2006) User Manual

Page 20

Advertising
background image

ARCMASTER 200 AC/DC

2-4

April 13, 2006

2.06 Functional Block Diagrams

Figure 2-2 illustrates the functional block diagram of the 200 AC/DC-power supply.

Main

Circuit

Switch

Filter

Input

Diode

Primary

Capacitor

DC Power

Voltage

Sensor

IGBT

Inverter

Thermal

Detector

To each control circuit

+/-15VDC +18VDC

+24VDC +5VDC

Trouble
Sensing

Circuit

Drive

Circuit

Torch Control

Connection

(CON1)

circuit

Current

Adjustment

Reference

Adjustment &

Mode select Switches

Panel Circuit Board

Sequence

Control

Themal

Sensor

Circuit

Main

Transformer

(PCB14)

Output

Diodes

HF-UNIT

Control

Circuit

Stick Mode

VRD

Sensing

Circuit

Lift T ig Mode

Output Short

Sensing

Circuit

Coupling

High

Coil

Frequency

Unit

Fan Control

Circuit

Gas Control

Circuit

Fan

Solenoid

Hall Current

Transformer

(HCT1)

Output

Inductor

Thermal

Detector

+

-

+

-

Input

Power

Secondary

DC Power

Voltage Sensor

To each control circuit

+/-12VDC +15VDC

Secondary

IGBT

Inverter

Drive

Circuit

Primary
Current
Sensor

Art # A-07267

Figure 2-2: 200 AC/DC Model Functional Block Diagram

2.07 Transporting Methods

This unit is equipped with a handle for carrying purposes.

!

WARNING

ELECTRIC SHOCK can kill. DO NOT TOUCH
live electrical parts. Disconnect input power
conductors from de-energized supply line
before moving the welding power source.

!

WARNING

FALLING EQUIPMENT can cause serious
personal injury and equipment damage.

• Lift unit with handle on top of case.

• Use handcart or similar device of adequate capacity.

• If using a fork lift vehicle, place and secure unit on a

proper skid before transporting.

Advertising