03 power source problems, 03 power source problems -7, Arcmaster 200 ac/dc – Tweco 200 ACDC Arcmaster(April2006) User Manual

Page 55

Advertising
background image

ARCMASTER 200 AC/DC

April 13, 2006

10-7

10.03 Power Source Problems

Description Possible

Cause

Remedy

1 The welding arc

cannot be
established.

A

B

The Primary supply voltage has
not been switched ON.
The Welding Power Source
switch is switched OFF.

A

B

Switch ON the Primary
supply voltage.
Switch ON the Welding
Power Source.

C Loose connections internally.

C Have an accredited Thermal

Arc Service Agent repair
the connection.

2 Maximum output

welding current can
not be achieved with
nominal Mains
supply voltage.

Defective

control

circuit.

Have an accredited Thermal

Arc Service Agent repair
the connection.

3 Welding current

reduces when
welding.

A

B

C

D

E

Loose welding cable
connections.

Incorrect welding cable size.

Improper input connections.

Poor electrode condition.
Wrong welding polarity.

A

B

C

D

E

Tighten all welding
cable connections.

Use proper size and
type of cable.

Refer to Section 2.05
Electrical Input Requirements.

Replace electrode.
Verify output torch
connections.

4 No gas flow when

the torch trigger
switch is depressed.

A
B

Gas hose is cut.
Gas passage contains
impurities.

A
B

Replace gas hose.
Disconnect gas hose from
the rear of Power Source then
raise gas pressure and blow
out impurities.

C Gas regulator turned OFF.

C Turn gas regulator ON.

D Torch trigger switch lead is

disconnected or switch/cable
is faulty.

D Reconnect lead or repair faulty

switch/cable.

Table 10-3: Power Source Problems