01 stick welding, 02 ac or dc hf tig welding, Arcmaster 200 ac/dc – Tweco 200 ACDC Arcmaster(April2006) User Manual

Page 38

Advertising
background image

ARCMASTER 200 AC/DC

6-2

April 13, 2006

6.01 Stick Welding

· Connect work lead to negative terminal

· Connect electrode lead to positive terminal

· Switch machine on

· Set AC or DC weld current. If AC is selected then set

AC FREQ

to 60Hz & WAVE BALANCE to 50%.

· Set Contractor

· Connect remote control device if required

Use the Scroll Buttons to move to the parameter to be
set. The LED will show which function is being adjusted
on the weld sequence graph. Use the control knob to
adjust each parameter.

· Set HOT START

· Set WELD current

Commence welding

6.02 AC or DC HF TIG Welding

· Connect work lead to positive terminal

· Connect TIG torch to negative terminal

· Switch machine on

· Set AC or DC weld current. If AC is selected then set

AC FREQ & WAVE BALANCE

· Connect remote control device if required

Use the Scroll Buttons to move to the parameter to be
set. The LED will show which function is being adjusted
on the weld sequence graph. Use the control knob to
adjust each parameter.

· Set

PRE-FLOW time

· Set

HOT START current

· Set

POST-FLOW time

· Set

(WELD) PEAK CUR current

· Set

POST-FLOW time

Slope Mode Parameters if required

· Set

INITIAL CUR current

· Set

UP SLOPE time

· Set (WELD)

PEAK CUR current

· Set

BASE current

· Set

DOWN SLOPE time

· Set

CRATER CUR current

Pulse Mode parameters if required

· Set

PULSE WIDTH % for PEAK CURRENT

·

Set PEAK CURRENT

· Set

PULSE FREQ

Commence welding

Advertising