ARCMASTER 200 AC/DC

April 13, 2006

3-3

3.05 Input Power

Each unit incorporates an INRUSH circuit and input voltage sensing circuit. When the MAIN CIRCUIT SWITCH is
turned on, the inrush circuit provides a pre-charging of the input capacitors. SCR’s in the Power Control Assembly
(PCA) will turn on after the input capacitors have charged to full operating voltage (after approximately 5 seconds).

NOTE

Note the available input power. Damage to the PCA could occur if 400VAC or higher is applied.

The following 208/230V Primary Current recommendations are required to obtain the maximum welding current and
duty cycle from this welding equipment:

The ARC MASTER 200 AC/DC is designed for use with a generator as an input power source. Contact an accredited
Thermal Arc service agent for the proper sizing and set-up recommendations of a generator power source system. As
a general rule, depending on the type of generator used, the generator capacity should be twice the maximum rating
of the welder.

3.06 High Frequency Introduction

The importance of correct installation of high frequency
welding equipment cannot be over-emphasized.
Interference due to high frequency initiated or stabilized
arc is almost invariably traced to improper installation.
The following information is intended as a guide for
personnel installing high frequency welding machines.

!

WARNING: EXPLOSIVES

The high frequency section of this machine
has an output similar to a radio transmitter.
The machine should NOT be used in the
vicinity of blasting operations due to the
danger of premature firing.

!

WARNING: COMPUTERS

It is also possible that operation close to
computer installations may cause computer
malfunction.

TIG

STICK

230/33

200 @ 30%

230/38

-

160 @ 40%

Minimum Primary

Current Circuit Size

(Vin/Amps)

Current & Duty Cycle

2.5mm sq/3

minimum

ArcMaster

200 AC/DC

Model

Primary Supply

Lead Size

(Factory Fitted)

Table 3-2: 230V/ Primary Current Circuit sizes to achieve maximum current