Arcmaster 200 ac/dc – Tweco 200 ACDC Arcmaster(April2006) User Manual
Page 59
ARCMASTER 200 AC/DC
April 13, 2006
11-3
C) Access the VRD control by gently prying back the front panel controls to reveal the VRD ON/OFF potentiometer.
(see Figure 11-3)
D) Turning the VRD ON/OFF. (see Figure 11-3)
• To turn VRD ON: rotate the trim potentiometer (VR1) on the display PCB fully clockwise. When VRD is turned ON
check that it operates as per VRD Specifications on page 11-1.
• To turn VRD OFF: rotate the trim potentiometer (VR1) on the display PCB fully counter-clockwise.
CAUTION
DO NOT pull back the front panel with excessive force as this will unplug control PCB. Plugging the control
PCB back into the front panel controls can only be achieved by removing the side covers.
VR1
Art # A-07081
Figure 11-3: VRD ON/OFF Step C and D
!
WARNING
The VRD ON/OFF trim potentiometer MUST ONLY be positioned fully clockwise OR fully counter-clockwise
as the VRD function will be unknown for every other position.