04 weld parameters for arcmaster 200 ac/dc, 04 weld parameters for arcmaster 200 ac/dc -6, Arcmaster 200 ac/dc – Tweco 200 ACDC Arcmaster(April2006) User Manual
Page 32
ARCMASTER 200 AC/DC
4-6
April 13, 2006
4.04 Weld Parameters for ArcMaster 200 AC/DC
Weld
HF
Parameter
STICK
TIG
PRE-FLOW
0.0 to 1.0 sec
0.1 sec
0.1 sec
No
Yes
Yes
HOT START
0 to 70A
20A
1A
Yes
Yes
No
INITIAL CUR.
5 to 185A
30A
1A
No
Yes
Yes
UP SLOPE
0 to 15 sec
1 sec
0.1 sec
No
Yes
Yes
PEAK CUR.
5 to 185A
120A
1A
No
Yes
Yes
WELD CUR
(TIG)
WELD CUR (STICK)
5 to 160A
80A
1A
Yes
No
No
SPOT TIME
0.5 to 5.0 sec
2 sec
0.1 sec
No
Yes
Yes
PULSE WIDTH
15 to 80%
50%
1%
No
Yes
Yes
See
Table 6
AC FREQUENCY
15 to 150Hz
50Hz
1Hz
Yes
Yes
Yes
WAVE BALANCE
10 to 65%
50%
1%
Yes
Yes
Yes
DOWN SLOPE
0 to 25 sec
3 sec
0.1 sec
No
Yes
Yes
CRATER CUR.
5 to 185A
30A
1A
No
Yes
Yes
POST-FLOW
0.0 to 60 sec
10 sec
0.1 sec
No
Yes
Yes
Yes
Yes
5 to 185A
80A
PULSE FREQ.
0.5 to 500Hz
100.0Hz
No
1A
No
Weld Mode
Parameter
Range
Factory
Setting
Incremental
Unit
LIFT TIG
Yes
Yes
Table 4-4: Weld Parameters for ArcMaster 200 AC/DC
PULSE FREQ.
Range
Incremental Unit
0.5 to 20Hz
0.1Hz
20 to 100Hz
1Hz
100 to 500Hz
5Hz