Arcmaster 200 ac/dc – Tweco 200 ACDC Arcmaster(April2006) User Manual
Page 34
ARCMASTER 200 AC/DC
4-8
April 13, 2006
Feature Description
Save/Load Function
• A total number of 5 programs can be saved into the
185AC/DC memory.
SAVE
the Current Weld Parameters into Memory
• Press and HOLD the
SAVE
button. Beep will sound and
the Digital Meter will show a number 1.
• Select a memory location by rotating the control knob,
1 to 5 is displayed on the meter.
• After selecting the desired memory location (i.e. 1 to 5),
press the right scroll button and the machine will give a
beep to confirm the weld parameters from the control
panel are saved.
LOAD
(retrieve) a Program to Control Panel
• Press and HOLD the
LOAD
button. Beep will sound and
the Digital Meter display will show a number 1.
• Select a memory location by rotating the control knob,
1 to 5 is displayed on the meter.
After selecting the desired memory location (i.e. 1 to 5),
press the right scroll button and the machine will give a
beep to confirm the weld parameters are loaded onto the
control panel.
Table 4-6:Power Source Features con't