Description Possible

Cause

Remedy

5 Gas flow won’t

shut OFF.

A Weld Mode (

STD

,

SLOPE

,

REPEAT

or

SPOT

) was changed

before

POST-FLOW

gas time

had finished.

A Strike an arc to complete the

weld cycle.
OR
Switch machine OFF then ON to
reset solenoid valve sequence.

B Gas valve is faulty.

B Have an accredited Thermal

Arc Service Agent repair or
replace the gas valve.

C Gas valve jammed open.

C Have an accredited Thermal

Arc Service Agent repair or
replace the gas valve.

D

POST-FLOW

control is set

to 60 sec.

D Reduce

POST-FLOW

time.

6 The TIG electrode has

been contaminated
due to the gas flow
shutting OFF before
the programmed

POST-FLOW

time

has elapsed.

The Weld Process Mode
(STICK, HF TIG or LIFT TIG) was
changed before

POST-FLOW

gas

time had finished.

Do not change Weld Process
Mode before the

POST-FLOW

gas time had finished.

Table 10-3 (continued): Power Source Problems