Section 11: voltage reduction device (vrd), 01 vrd specification, 02 vrd maintenance – Tweco 200 ACDC Arcmaster(April2006) User Manual

Page 57: Section 11, Voltage reduction device (vrd) -1, 01 vrd specification -1 11.02 vrd maintenance -1, Arcmaster 200 ac/dc

Advertising
background image

ARCMASTER 200 AC/DC

April 13, 2006

11-1

SECTION 11:

VOLTAGE REDUCTION DEVICE (VRD)

11.01 VRD SPECIFICATION

ArcMaster

Description

200 AC/DC

Notes

VRD Open Circuit Voltage

15.3 to 19.8V

Open circuit voltage between welding
terminals.

VRD Resistance

148 to 193 ohms The required resistance between

welding terminals to turn ON the
welding power.

VRD Turn OFF Time

0.2 to 0.3

seconds

The time taken to turn OFF the welding
power once the welding current has
stopped.

Table 11-1: VRD Specification

11.02 VRD MAINTENANCE

Routine inspection and testing (power source):

An inspection of the power source, an insulation resistance test and an earth resistance test should be carried out.

a. For transportable equipment, at least once every 3 months.

b. For fixed equipment, at least once every 12 months.

The owners of the equipment shall keep a suitable record of the periodic tests.

NOTE

A transportable power source is any equipment that is not permanently connected and fixed in the position
in which it is operated.

In addition to the above tests and specifically in relation to the VRD fitted to this machine, the following periodic tests
should also be conducted by an accredited Thermal Arc service agent.

Description

IEC 60974-1 Requirements

VRD Open Circuit Voltage

Less than 20V; at Vin=230V

VRD Turn ON Resistance

Less than 200 ohms

VRD Turn OFF Time

Less than 0.3 seconds

Table 11-2: Periodic Tests

If this equipment is used in a location or an environment with a high risk of electrocution then the above tests should
be carried out prior to entering this location.