Arcmaster 200 ac/dc – Tweco 200 ACDC Arcmaster(April2006) User Manual

Page 30

Advertising
background image

ARCMASTER 200 AC/DC

4-4

April 13, 2006

4.03 Weld Parameter Descriptions for ArcMaster 200 AC/DC

Art # A-07237

Figure 4-3: ArcMaster 200 AC/DC Front Panel

Parameter

Description

PRE-FLOW

This parameter operates in all weld modes except Lift TIG mode and is
used to heat up the weld zone in TIG modes or improve the start
characteristics for stick electrodes. e.g. low hydrogen electrodes. It sets
the peak start current on top of the

BASE (WELD)

current.

e.g.

HOT START

current = 130 amps when

BASE (WELD)

= 100 amps &

HOT START

= 30 amps

INITIAL CUR.

This parameter operates in

SLOPE

or

REPEAT

(4T) TIG modes only and

is used to set the start current for TIG. The Start Current remains on until
the torch trigger switch is released after it has been depressed.

UP SLOPE

This parameter operates in TIG modes only and is used to set the time
for the weld current to ramp up, after the torch trigger switch has been
pressed then released, from INITIAL CUR to PEAK or BASE current

This parameter operates in TIG modes only and is used to provide gas
to the weld zone prior to striking the arc, once the torch trigger switch
has been pressed. This control is used to dramatically reduce weld
porosity at the start of a weld.

HOT START

Table 4-3: ArcMaster 200 AC/DC Front Panel Parameter Description

Advertising