ARCMASTER 200 AC/DC

April 13, 2006

4-5

PEAK CUR.

This parameter sets the PEAK weld current when in

PULSE

mode

WELD

This parameter sets the TIG WELD current in

STD

,

SLOPE

,

REPEAT

and

SPOT

modes when

PULSE

is OFF. This parameter also sets the STICK

weld current.

BASE

(BackgroundCurrent)

This parameter sets the Background current when in Pulse TIG mode.

SPOT TIME

This parameter sets the duration of the

SPOT TIME

in

HF TIG

mode only

PULSE WIDTH

This parameter sets the percentage on time of the

PULSE FREQUENCY

for PEAK weld current when the

PULSE

is ON.

PULSE FREQ.

This parameter sets the

PULSE FREQUENCY

when the

PULSE

is ON.

AC FREQUENCY

This parameter operates in AC mode only and is used to set the
frequency for the AC weld current.

DOWN SLOPE

This parameter operates in TIG modes only and is used to set the time
for the weld current to ramp down, after the torch trigger switch has
been pressed, to

CRATER CUR.

This control is used to eliminate the

crater that can form at the completion of a weld.

CRATER CUR.

This parameter operates in

SLOPE

or

REPEAT

(4T) TIG modes only and

is used to set the finish current for TIG. The CRATER Current remains ON
until the torch trigger switch is released after it has been depressed.

The SAVE/LOAD buttons are used to save and retrieve a total number of
5 programs into the 200AC/DC memory.

WAVE BALANCE

This parameter is used for aluminum AC TIG mode and is used to set the
penetration to cleaning action ratio for the AC weld current. Generally

WAVE BALANCE

is set to 50% for AC

STICK

welding. The

WAVE

BALANCE

control changes the ratio of penetration to cleaning action of

the AC TIG welding arc. Maximum weld penetration is achieved when
the

WAVE BALANCE

control is set to 10%. Maximum cleaning of heavily

oxidised aluminium or magnesium alloys is achieved when the

WAVE

BALANCE

control is set to 65%.

POST-FLOW

This parameter operates in TIG modes only and is used to adjust the
post gas flow time once the arc has extinguished. This control is used to
dramatically reduce oxidation of the tungsten electrode.

WAVE BALANCE=10%

Maximu m Penetratio n and

redu ced cleaning

WAVE BALANCE=50%

Balanced with 50% pen etration

an d 50% cle an in g

WAVE BALANCE=65%

Maximum Cle aning and

reduced penetration

10%

50%

65%

90%

50%

35%

(+ )

(+ )

(+ )

(-)

(-)

(-)