POWERMASTER 400SP, 500SP AUTOMATION

2-4

March 16, 2007

2.06 Power Supply Specifications (part 1)

Input Mains Voltage (50/60 Hz)

V 208 230 400 460 208 230 400 460

Mains Voltage Tolerance Range

%

Max Recommended Circuit Breaker or Time-Delay Fuse

3 Phase

A

45

40

25

20

70

60

35

30

Max Recommended Standard Normal Operating Fuse

3 Phase

A

55

50

30

25

80

70

40

35

Max Recommended Circuit Breaker or Time-Delay Fuse

1 Phase

A 100 90

50

45 100 90

50

45

Max Recommended Standard Normal Operating Fuse

1 Phase

A 110 100 60

50 110 100 60

50

Power factor at Maximum Output

cos

Maximum Open Circuit Voltage

OCV

V

Voltage Range for GMAW-P, GMAW, FCAW, MIG

U 2min-U 2max

V

Current Range for GMAW-P, GMAW, FCAW, MIG

I 2min-I 2max

A

Current Range for SMAW (Stick)

I 2min-I 2max

A

Enclosure Protection Class to EN 60 529
Insulation Class
Cooling Method
Noise Emission

dB (A)

Welding Output
Duty Cycle 100%

3 Phase

A

Duty Cycle 60%

3 Phase

A

Duty Cycle at Maximum Current

3 Phase

X

Input Mains Voltage (50/60 Hz)

3 Phase

V 208 230 400 460 208 230 400 460

Input Power S1 at 100% Duty Cycle

3 Phase

kVA 11

11

12

12

16

16

16

17

Input Power S1 at 60% Duty Cycle

3 Phase

kVA 13

13

14

14

24

23

23

24

Input Power S1 at Maximum Current

3 Phase

kVA 17

16

17

17

24

23

23

24

Generator Requirement with Three Phase

3 Phase

kVA

Input Current I1 at 100% Duty Cycle

3 Phase

A

32

29

18

16

45

40

23

21

Input Current I1 at 60% Duty Cycle

3 Phase

A

37

33

20

17

66

59

34

30

Input Current I1 at Maximum Output

3 Phase

A

46

41

24

21

66

59

34

30

Welding Output
Duty Cycle 100%

1 Phase

A

Duty Cycle 60%

1 Phase

A

Duty Cycle at Maximum Current

1 Phase

X

Input Mains Voltage (50/60 Hz)

1 Phase

V 208 230 400 460 208 230 400 460

Input Power S1 at 100% Duty Cycle

1 Phase

kVA 13

14

14

14

13

14

14

14

Input Power S1 at 60% Duty Cycle

1 Phase

kVA 15

16

16

16

15

16

16

16

Input Power S1 at Maximum Output

1 Phase

kVA 19

20

20

20

19

20

20

20

Generator Requirement with Single Phase

1 Phase

kVA

Input Current I1 at 100% Duty Cycle

1 Phase

A

65

61

35

30

65

61

35

30

Input Current I1 at 60% Duty Cycle

1 Phase

A

74

68

40

35

74

68

40

35

Input Current I1 Maximum Output

1 Phase

A

92

85

50

43

92

85

50

43

PowerMaster Power Source Part Numbers

W1000402

W1000602

Automation Power Supply with Integrated Torch Water Cooling System

30

Electrical Specifications for GMAW-P / GMAW / FCAW / MIG with Three-Phase Input Power

25

35

400SP

500SP

30

320

400SP

0.99

0.99

79

14.3 – 34

5 – 400

10-380

Input Mains Power

400SP

500SP

Summary Specifications

320
350

Electrical Specifications for GMAW-P / GMAW / FCAW / MIG with Single-Phase Input Power

500SP

50%@400A, 34V

60%@500A, 39V

320

Input Mains Power

50%@400A, 34V

79

400
500

5 – 500

14.3 – 39

<70

IP23

10-480

350

+/- 10

350

50%@400A, 34V

+/- 10

F

Fan Cooled

<70

IP23

F

Fan Cooled