POWERMASTER 400SP, 500SP AUTOMATION

March 16, 2007

7-1

Warning!
Disconnect input power before maintaining.

Each Use

Visual check of
regulator and pressure

Visual check of torch
electrode and shield cup

Weekly

Visually inspect the torch
body and consumables

Visually inspect the
cables and leads.
Replace as needed

3 Months

Clean
exterior
of power supply

6 Months

Replace all
broken parts

Visually check and
Carefully clean the
interior

Maintain more often
if used under severe
conditions

Gas and
air lines

Art # A-07725

Visually inspect the Wire
feed mechanisms

WA

RN

ING

PO

WE

R

10

A

RE

MO

TE

LO

CA

L

CO

NT

AC

TO

R

SECTION 7:

SERVICE

7.01 Maintenance

NOTE

For units with integrated coolers, check the fluid levels and refill as needed. Check torch connec-
tions for leaks and then check for return flow of coolant to the resevoir.