Tweco 500SP PowerMaster Automation User Manual

Page 29

Advertising
background image

POWERMASTER 400SP, 500SP AUTOMATION

March 16, 2007

3-5

3.06 Connecting Single-Phase Input Power to 400SP or 500SP

!

WARNINGS

Installation must meet all National and Local Codes - have only qualified persons make this instal-
lation.

Disconnect and lockout/tagout input power before connecting input conductors from unit.

Always connect green or green/yellow conductor to supply grounding terminal first, and never to a
line terminal.

Make input power connections to the welding power source first.

Input Mains Voltage (50/60 Hz)

V

208

230

400

460

208

230

400

460

Max Recommended Circuit Breaker or Time-Delay Fuse

A

100

90

50

45

100

90

50

45

Max Recommended Standard Normal Operating Fuse

A

110

100

60

55

110

100

60

55

Min Input Conductor Size

AWG

4

4

8

10

4

4

8

10

Min Input Conductor Size

AWG

6

6

8

10

6

6

8

10

Suggested Input Cord Type

Single-Phase

Carolprene® Jacketed Type SOOW 90°C 600 Volt

UL/CSA Portable Cord

400SP

Single-Phase

500SP

Art# A-07883

Primary Power Cable
(customer supplied)

Line Fuse

Line
Disconnect
Switch

Ground
Conductor

Ground
Terminal

GND/PE

Advertising
This manual is related to the following products: