POWERMASTER 400SP, 500SP AUTOMATION

5-4

March 16, 2007

LEDs on Robot Interface INT06 PC Board





LED

Designation

State

Meaning

lit weak Microcontroller not programmed

blinking supply voltage not ok

1 (red)

malfunction

off

INT06 ok

on

internal supply voltage +5V DC is ok

2 (green) supply voltage

+5V

off

internal supply voltage +5V DC is not ok

on

relay RE1 is on : output „I>0“ (welding current
on) is active (0

Ω)

3 (green) power source

ready

off

relays RE1 is off : output „I>0“ (welding current
on) is not active (open)

on

relay RE2 is on : output „power source ok“ is
active (0

Ω)

4 (green) power source ok

off

relay RE2 is off : output „power source ok“ is not
active (open)

5 (green) polarity digital

signals "IN-NPN"

on

relay RE6 is on : digital inputs are low-active
(working with GND)

off

relay RE6 is off : digital inputs are high-active
(working with +24V DC)

15
(green)

status

blinking status ok

off

status not ok

16
(green)

arc sensing
"ARC-SENSE"

on

relay RE3 is on : output „Arc Sensing“ is active
(0

Ω)

off

relay RE3 is off : output „Arc Sensing“ is not
active (open)

17
(green)

short circuit wire
"W-STICK"

on

relay RE4 is on : output „Wire Stick“ is active (0
Ω)

off

relay RE4 is off : output „Wire Stick“ is not active
(open)

18
(green)

wire sensing "W-
STATE"

on

relay RE5 is on : output „Wire State“ is active (0
Ω)

off

relay RE5 is off : output „Wire State“ is not
active (open)

Advertising