The INT06 can also be programmed at the front panel in menu "Extras, Robot Interface". The eight analog
inputs can be enabled or disabled. So it is not necessary to open the machine and set the DIP switches. If there
are not enough digital outputs available at the robot control to select a welding program, it is possible to select
three different pre-defined welding programs with only two digital outputs. Those welding programs can be
set at menu items "ProgIn1" to "ProgIn3". The selection of these welding programs is made over the digital
inputs 1 and 2 (pin 1 and 2).

Menu Item

Pin No. Setting

Description

On

analog input is enabled (corresponds with DIP switch 1 set to “ON”)

Opt01(AnalogIn1) 23

Off analog input is disabled

On

analog input is enabled (corresponds with DIP switch 2 set to “ON”)

Opt02(AnalogIn2) 24

Off analog input is disabled

On

analog input is enabled (corresponds with DIP switch 3 set to “ON”)

Opt03(AnalogIn3) 25

Off analog input is disabled

On

analog input is enabled (corresponds with DIP switch 4 set to “ON”)

Opt04(AnalogIn4) 26

Off analog input is disabled

On

analog input is enabled (corresponds with DIP switch 5 set to “ON”)

Opt05(AnalogIn5) 27

Off analog input is disabled

On

analog input is enabled (corresponds with DIP switch 6 set to “ON”)

Opt06(AnalogIn6) 28

Off analog input is disabled

On

analog input is enabled (corresponds with DIP switch 7 set to “ON”)

Opt07(AnalogIn7) 29

Off analog input is disabled

On

analog input is enabled (corresponds with DIP switch 8 set to “ON”)

Opt08(AnalogIn8) 30

Off analog input is disabled

On

program selection is enabled (corresponds with DIP switch 9 set to “ON”)

Opt09(ProgSelect)

Off program selection is disabled

On operating mode selection is enabled (corresponds with DIP switch 10 set to “ON”)

Opt10(OperMode)

Off operating mode selection is disabled

On

“robot mode” is active (corresponds with the signal “set extern”)

Opt11(Setextern)

Off “manual hand mode” is active

On When using job selection (tiptronic mode) it is possible during the welding, to change enabled

parameters over the analog inputs. For example during the welding process the welding current can
be altered with the control voltage at the analog input 1 [Opt01(AnalogIn1) must be set to “ON”]

Opt12(Job+Analog)

Off Normal tiptronic mode, all welding parameters are stored in the job and can’t be changed over the

analog inputs.

ProgIn1 = Prog (0-99)

Assignment of a welding program
welding program no. (0-99) set as program 1

ProgIn2 = Prog (0-99)

Assignment of a welding program
welding program no. (0-99) set as program 2

ProgIn3 = Prog (0-99)

Assignment of a welding program
welding program no. (0-99) set as program 3