POWERMASTER 400SP, 500SP AUTOMATION

March 16, 2007

5-9

Other Analog Parameters

Designation Description

Signal

Function

0V 0

sec.

pre gas time

Control voltage 0-10V for the pre gas time.

10V DC

10 sec.

0V 20%

gas post time

Control voltage 0-10V for the gas post time.

10V DC

300%

0V

5% of welding current

twinpulse current change Control voltage 0-10V for the twinpulse current change.

The operating mode twinpulse must be active.

10V DC

50% of welding current

0V 20%

twinpulse relation Control voltage 0-10V for the twinpulse relation.

The operating mode twinpulse must be active.

10V DC

80%

0V

20% of programmed value

wire burnback time

Control voltage 0-10V for the wire burnback time.

10V DC

300% of programmed value

0V

20% of programmed value

inductor effect

Control voltage 0-10V for the inductor effect.

10V DC

200% of programmed value