Tweco 500SP PowerMaster Automation User Manual

Page 27

Advertising
background image

POWERMASTER 400SP, 500SP AUTOMATION

March 16, 2007

3-3

3.05 Connecting 3-Phase Input Power to 400SP or 500SP

!

WARNINGS

Installation must meet all National and Local Codes - have only qualified persons make this instal-
lation.

Disconnect and lockout/tagout input power before connecting input conductors from unit.

Always connect green or green/yellow conductor to supply grounding terminal first, and never to a
line terminal.

Make input power connections to the welding power source first.

Input Mains Voltage (50/60 Hz)

V

208

230

400

460

208

230

400

460

Max Recommended Circuit Breaker or Time-Delay Fuse

A

45

40

25

20

70

60

35

30

Max Recommended Standard Normal Operating Fuse

A

55

50

30

25

80

70

40

35

Min Input Conductor Size

AWG

8

8

12

14

4

6

10

10

Min Input Conductor Size

AWG

8

8

12

14

6

8

10

10

Suggested Input Cord Type

Carolprene® Jacketed Type SOOW

90°C 600 Volt UL/CSA Portable Cord

Three-Phase

Three-Phase

400SP

500SP

Art: A-07877

Primary Power Cable
(customer supplied)

Line Fuse

Line
Disconnect
Switch

Ground
Conductor

Ground
Terminal

GND/PE

Advertising
This manual is related to the following products: