INSTALLATION, OPERATION AND SETUP

SECTION 3: INSTALLATION, OPERATION AND SETUP

3.01 Environment

This Power Source is designed for use in environments

with increased hazard of electric shock.
A. Examples of environments with increased hazard of

electric shock are:

1. In locations in which freedom of movement

is restricted, so that the operator is forced to

perform the work in a cramped (kneeling, sitting

or lying) position with physical contact with

conductive parts.

2. In locations which are fully or partially limited

by conductive elements, and in which there is

a high risk of unavoidable or accidental contact

by the operator.

3. In wet or damp hot locations where humidity

or perspiration considerable reduces the skin

resistance of the human body and the insulation

properties of accessories.

B. Environments with increased hazard of electric

shock do not include places where electrically

conductive parts have been insulated.

3.02 Location

Be sure to locate the welder according to the following

guidelines:
A. In areas, free from moisture and dust.
B. Ambient temperature between 32 to 104° F (0 to

40° C).

C. In areas, free from oil, steam and corrosive gases.
D. In areas, not subjected to abnormal vibration or

shock.

E. In areas, not exposed to direct sunlight or rain.
F. Place at a distance of 12"(300mm) or more from

walls or similar that could restrict natural air flow

for cooling.

G. The enclosure design of this Power Source meets the

requirements of IP23S as outlined in EN 60529. This

provides adequate protection against solid objects

(greater than 1/2", 12mm), and direct protection

from vertical drops. Under no circumstances should

the Power Source be operated or connected in

a micro environment that will exceed the stated

conditions. For further information please refer to

EN 60529.

H. Precautions must be taken against the power source

toppling over. The power source must be located on

a suitable horizontal surface in the upright position

when in use.

WARNING

This equipment should be electrically

connected by a qualified electrician.

3.03 Ventilation

!

WARNING

Since the inhalation of welding fumes can

be harmful, ensure that the welding area is

effectively ventilated.

3.04 Electricity Supply Voltage

The Electricity Supply voltage

should be within 95-140V AC.

Too low a voltage may cause

poor welding performance in STICK mode. Too high a

supply voltage will cause components to overheat and

possibly fail.
The Welding Power Source must be:

• Correctly installed, if necessary, by a qualified

electrician.

• Correctly earthed (electrically) in accordance with

local regulations.

• Connected to the correct size power point and fuse

as per the Specifications on page 2-4.