INSTALLATION, OPERATION AND SETUP

3-12

Manual 0-5145

13. Digital Voltage Meter (Right Digital Display)

The digital voltage meter is used to display the both the preview voltage (MIG mode only) and actual output

voltage (all modes) of the Power Source.

At times of non-welding, the voltage meter will display a preview value in MIG mode. This value can be

adjusted by varying the multifunction control knob (Control No. 9). Note that in STICK and LIFT TIG modes,

the voltage meter will not preview welding voltage but will display Open Circuit Voltage in STICK mode and

0V in LIFT TIG mode.
When welding, the voltage meter will display actual welding voltage in all modes.

At the completion of welding, the digital voltage meter will hold the last recorded voltage value for a period of

approximately 10 seconds in all modes. The voltage meter will hold the value until; (1) any of the front panel

controls are adjusted in which case the Power Source will revert to preview mode, (2) welding is recommenced,

in which case actual welding amperage will be displayed, or (3) a period of 10 seconds elapses following the

completion of welding in which case the Power Source will return to preview mode.

NOTE

The preview functionality provided on this power source is intended to act as a guide only. Some

differences may be observed between preview values and actual welding values due to factors including

the mode of welding, differences in consumables/gas mixtures, individual welding techniques and the

transfer mode of the welding arc (ie dip versus spray transfer). Where exact settings are required (in

the case of procedural work), it is recommended that alternate measurement methods be utilized to

ensure output values are accurate.

14. Fault Indicator

This welding Power Source is protected by a self resetting thermostat. The indicator will illuminate if the duty

cycle of the Power Source has been exceeded or if a fault is detected in the Inverter. Should the Fault Indicator

illuminate the output of the Power Source will be disabled. Once the Power Source cools down this light will

go OFF and the over temperature condition will automatically reset. Note that the power switch should remain

in the on position such that the fan continues to operate thus allowing the Power Source to cool sufficiently.

Do not switch the Power Source off should a thermal overload condition be present. If the fault condition

does not extinguish, then the Power Supply will need to be taken to an authorized repair center for analysis.

15. Gas Inlet (MIG mode only for MIG Gun or Spool Gun operation)

The Gas Inlet connection is used to supply the appropriate MIG welding gas to the Power Source. Refer to

section 3.19 to 3.20 for MIG (FCAW/GMAW) set up details.

!

WARNING

Only Welding Shielding Gases specifically designed for arc welding applications should be used.

16. On / Off Switch

This switch is used to turn the Power Source on/off.

WARNING

When the front digital displays are lit, the machine is connected to the Mains supply voltage and the

internal electrical components are at Mains voltage potential.