Fabricator 141i – Tweco Fabricator 141i Operating Manual User Manual

Page 51

Advertising
background image

Fabricator 141i

Manual 0-51

45

3-21

INSTALLATION, OPERATION AND SETUP

3.19 Setup for MIG (GMAW) Welding with Gas Shielded MIG Wire

A. Select MIG mode with the process selection control. (Refer to Section 3.10 for further information)
B. Connect the MIG Gun Polarity Lead to the positive welding terminal (+). If in doubt, consult the electrode wire

manufacturer. Welding current flows from the Power Source via Dinse style connectors. It is essential, however,

that the male plug is inserted and turned securely to achieve a sound electrical connection.

C. Fit the MIG Gun to the Power Source. (Refer to Section 3.11 Attaching the Fusion 140A MIG Gun).
D. Connect the work lead to the negative welding terminal (-). If in doubt, consult the electrode wire manufacturer.

Welding current flows from the Power Source via Dinse style connectors. It is essential, however, that the

male plug is inserted and turned securely to achieve a sound electrical connection.

E. Fit the flowmeter/ regulator to the shielding gas cylinder (Refer to Section 3.06) then connect the shielding gas

hose from the rear of the Power Source to the flowmeter/ regulator outlet.

F. Refer to the Weld Guide located on the inside of the wirefeed compartment door for further information.
G. Switch the LOCAL/REMOTE switch inside the

wire feed compartment to LOCAL to use the

Power Sources Wirespeed and Voltage controls.

H. Switch the MIG GUN/SPOOL GUN switch inside

the wire feed compartment to MIG GUN.

!

WARNING

Before connecting the work clamp to the work piece, make sure you have ceased feeding wire so

premature arcing will not occur.
Secure the shielding gas cylinder in an upright position by chaining it to a suitable stationary support

to prevent falling or tipping.

CAUTION

Loose welding terminal connections can cause overheating and result in the male plug being fused in

the terminal.

Advertising