INSTALLATION, OPERATION AND SETUP

3.12 Inserting Wire into the Wire Feed Mechanism

Release the tension from the Pressure Roller Arm by turning the adjustable Wire Drive Tension Screw in a

counterclockwise. Then to release the pressure roller arm push the tension screw toward the front of the machine

which releases the pressure roller arm. With the MIG welding wire feeding from the bottom of the spool (Figure

3-10) pass the electrode wire through the inlet guide, between the rollers, through the outlet guide and into the

MIG Gun. Re-secure the pressure roller arm and wire drive tension screw and adjust the pressure accordingly

(Figure 3-9). Remove the nozzle and contact tip from the MIG Gun. With the MIG Gun lead reasonably straight,

feed the wire through the MIG Gun by depressing the trigger switch. Fit the appropriate contact tip.

WARNING

Before connecting the work clamp to the work piece, make sure you have ceased feeding wire so

premature arcing will not occur.
The electrode wire will be at welding voltage potential while it is being fed through the system.
Keep MIG Gun away from eyes and face.

Art # A-10359

Outlet Guide

Inlet Guide

Wire Drive Tension Screw

Pressure Roller Arm

Figure 3-9: Wire Drive Assembly Components

MIG Welding Wire

Art #

A-10360

Figure 3-10: MIG Welding Wire - Installation