22 setup for lift tig (gtaw) welding, Setup for lift tig (gtaw) welding -26, Fabricator 141i – Tweco Fabricator 141i Operating Manual User Manual

Page 56

Advertising
background image

Fabricator 141i

INSTALLATION, OPERATION AND SETUP

3-26

Manual 0-5145

3.22 Setup for LIFT TIG (GTAW) Welding

A. Select LIFT TIG mode with the process selection control (refer to Section 3.10.12 for further information).
B. Using the supplied 50mm to 25mm DINSE adapter, connect the TIG torch to the negative welding terminal

(-). Welding current flows from the Power Source via Dinse style connectors. It is essential, however, that the

male plug is inserted and turned securely to achieve a sound electrical connection.

C. Connect the work lead to the positive welding terminal (+). Welding current flows from the Power Source via

Dinse style terminals. It is essential, however, that the male plug is inserted and turned securely to achieve a

sound electrical connection.

D. Connect the TIG torch trigger switch via the 8 pin socket located on the front of the Power Source. The TIG

torch will require a trigger switch to weld in LIFT TIG Mode.

NOTE

A Tweco 17V TIG torch with an 8 pin plug must be used to turn the weld current on/off via the TIG torch

trigger switch to TIG weld OR a Tweco Foot Control with an 8 pin plug must be used to turn the weld

current on/off as well as providing remote control of the weld current. Please refer to "2.10 Options

and Accessories".

E. Fit the flowmeter/ regulator to the shielding gas cylinder (refer to Section 3.06) then connect the shielding

gas hose from the TIG torch to the flowmeter/ regulator outlet. Note that the TIG torch shielding gas hose is

connected directly to the flowmeter/ regulator. The Power Source is not fitted with a shielding gas solenoid to

control the gas flow in LIFT TIG mode therefore the TIG torch will require a gas valve.

!

WARNING

Before connecting the work clamp to the work piece, make sure you have ceased feeding wire so

premature arcing will not occur.
Secure the shielding gas cylinder in an upright position by chaining it to a stationary support to prevent

falling or tipping.

CAUTION

Remove any packaging material prior to use. Do not block the air vents at the front or rear of the

Welding Power Source.
Loose welding terminal connections can cause overheating and result in the male plug being fused in

the terminal.

F. Switch the LOCAL/REMOTE switch inside the

wire feed compartment to LOCAL to use the

Power Sources Amperage control or REMOTE

for remote amperage using a Foot Control.