Unitec POS4000/V2 User Manual

Page 102

Advertising
background image

POS4000

Document

Number:

POS4003

94

Document Title:

POS4000/V2 Operations Manual



Make sure you return the DIP switches to normal operation mode when testing is
complete. For the normal operations, set the switches as follows:

Switch Setting
4

OFF

5

OFF



While the interface board is in the test mode, the customer buzzer will beep
approximately every 5 seconds. Once in the test mode, you select the specific
test desired by typing the following codes at the customer keypad:

CODE

TEST

10

Output relay line 1 on

20

Output relay line 2 on

30

Output relay line 3 on

40

Output relay line 4 on

50

Output relay line 5 on

60

Output relay line 6 on

70

Output relay line 7 on

80

Output relay line 8 on

90

Re-enter code relay output on

110

Code Accepted/wait relay output on

120

Enter Wash relay output on

130

Out-of-Service relay output on

140

All relay outputs on

150

Wash In-Use input status

160

Coin credit input status

170

Bill credit input status

180

Audit 1 input status

190

Audit 2 input status

210

Audit 3 input status

220

Audit 4 input status

230

Audit 5 input status