Step #4 outside keypad escutcheon – SARGENT Keypad Exit Devices User Manual

Page 15

Advertising
background image

Copyright © 2006, 2008, Sargent Manufacturing Company

, an A

SSA ABL

O

Y Group company

. All rights reserved.

Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.

800-810-WIRE (9473) • www.sargentlock.com • A7137B

Step #4 Outside Keypad Escutcheon

Outside

of door

Fire
stop
plate

Lower
lug

C

Lower

lug

L

Wires & connector
go through fire
stop plate

INSIDE OF

DOOR

OUTSIDE OF

DOOR

1

2

3

4

5

6

7

8

9

0

*

#

Flat

washer

#8-32 x 1-1/4''

Pan head screw

Connector &
wires through
fire stop plate

6. Insert Wires and Connector

• From the outside of the door through

the Fire Stop Plate (if required)

• For non 12- exit devices feed wire

harness from keypad assembly
through hole in door

• From the inside of the door, use

the #8-32 x 1-1/4" pan head
screw with the flat washer to
attach the Escutcheon using
the lower lug

• Straighten keypad

Escutcheon and tighten
the #8-32 x 1-1/4"
pan head screw

Inside

of door

Outside

of door

Inside of

door

13

4

Mortise Installation Instructions for

KP8900 Series (Continued)