Programming instructions (continued) – SARGENT Keypad Exit Devices User Manual

Page 19

Advertising
background image

Copyright © 2006, 2008, Sargent Manufacturing Company

, an A

SSA ABL

O

Y Group company

. All rights reserved.

Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.

800-810-WIRE (9473) • www.sargentlock.com • A7137B

To Enter the Supervisory Code:
99# Master Code

*

Yellow LED begins to blink slowly

50# 1# 03# Supervisory Code

*

Yellow LED blinks quickly

Supervisory Code

*

Yellow LED blinks slowly

*

Yellow LED goes out

To Enter a User Code:
99# Supervisory or Master Code

*

Yellow LED begins to blink slowly

50# 1# User Number (04-97)# User Code

*

Yellow LED blinks quickly

User Code

*

Yellow LED blinks slowly

*

Yellow LED goes out

To Enter a Passage (Maintained Mode) Code:
When Passage Mode is used, the same User Code must be used to Re-lock the lock.

99# Supervisory or Master Code

*

Yellow LED begins to blink slowly

50# 2# User Number (04-97)# User Code

*

Yellow LED blinks quickly

User Code

*

Yellow LED blinks slowly

*

Yellow LED goes out

To Enter a One-Time User Code:
99# Supervisory or Master Code

*

Yellow LED begins to blink slowly

50# 3# User Number# User Code

*

Yellow LED blinks quickly

User Code

*

Yellow LED blinks slowly

*

Yellow LED goes out

To Deactivate “Beep” with the Depression of Each Key:
99# Supervisory or Master Code

*

Yellow LED begins to blink slowly

30# 0# 0#

Yellow LED continues to blink slowly

*

Yellow LED blinks quickly

*

No beep on depression and yellow LED blinks slowly

*

No beep on depression and yellow LED goes out

To Reactivate “Beep” with the Depression of Each Key:
99# Supervisory or Master Code

*

Yellow LED begins to blink slowly

30# 0# 1#

Yellow LED continues to blink slowly

*

Yellow LED blinks quickly

*

Beep on depression and yellow LED blinks slowly

*

Beep on depression and yellow LED goes out

To Clear the Entire Memory:
99# Master Code

*

Yellow LED begins to blink slowly

46# 00000# 00000#

Yellow LED continues to blink slowly

*

Yellow LED blinks quickly

*

No beep on depression and yellow LED goes out

PAUSE

Yellow LED begins to blink slowly again

*

Yellow LED goes out

NOTE: This deletes ALL codes, including Master, Emergency and Supervisory. The Master Code is set back to 1234, Door Number to 0001 and Unlock time

to 5 sec. If the Master Code is not known, Factory Assistance will be required to clear the memory. 1-800-810-WIRE.

To Program Door Numbers into Keypad:
99# Master Code

*

Yellow LED begins to blink slowly

43# 0# Door Number# (Must be four digits)

Yellow LED blinks slowly

*

Yellow LED begins to blink quickly

*

Yellow LED blinks slowly

*

Yellow LED goes out