Passport 1000 pg mortise lock, 8 – installation of inside component assembly, 9 - installation of connectors – SARGENT Passport 1000 PG Mortise Locks User Manual

Page 12

Advertising
background image

PERSONA PG Controller DIP
Switch Settings (Fig 10A):

8 – Installation of Inside Component Assembly

Insert bottom of component assembly first (Fig. 8A), then
clip top of component assembly to backplate, verifying
both tabs attached securely.

9 - Installation of Connectors

Secure the following connectors onto the
circuit board (Fig. 9A1 and 9A2):
Note: Connectors go on only one way.
Do not force and do not offset connectors.
Be sure they are completely seated (flush).
1. Secure the mortise lock body as-

sembly connector (10-pin).

2. Secure the mortise keypad/card

reader connector (14-pin).

3. Secure the LCU connector (7-pin).

10 - Battery / Battery Pack Installation and DIP Switch

Setting Verification

1. Place (6) “AA” batteries into the compartment being careful to align

polarity (- & +) properly.

2. Insert battery pack and click into place, making sure polarity terminals on

the battery pack are oriented upwards (Fig. 10A).

3. Verify DIP switch settings are correct for the application.

Fig. 10A

Inside of door

PERSONA PG

controller DIP

switch location

Fig. 8A

From outside trim

(ground)

Detail

From outside trim

(card reader)

From outside

trim (keypad)

From lock body

Fig. 9A1

Fig. 9A2 (Detail)

ON
OFF

ON
OFF

SARGENT mortise lock with and

without deadbolt:

• Switch 1 and 2 - OFF
• Switch 3 - ON
SARGENT cylinder or exit locks:
• Switch 1 - OFF
• Switch 2 and 3 - ON

10/31/12

A7807C 12

Copyright © 2012, Sargent Manufacturing Company

, an ASSA ABLOY Group company

. All rights reser

ved.

Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.

Passport 1000 PG Mortise Lock