Passport 1000 pg mortise lock, 3 - installation of lock body – SARGENT Passport 1000 PG Mortise Locks User Manual

Page 9

Advertising
background image

Fig. 3A

Fig. 4A

Align through bolt posts on outside
lever assembly with door prepped holes
(Fig.4A).
1. Slide the outside lever assembly with

spindle though the door and lock
body.

2. Secure lever assembly with the inside

adapter plate with (2) screws:

DO NOT TIGHTEN.

3. Securely tighten the lock body screws on

edge of door.

5. Place rose over inside adapter and

tighten clockwise.

6. Fasten inside lever to inside adapter and

tighten lever set screw snugly.

Mortise lock body

connector and

grounding lug

3 - Installation of Lock Body

4. Securely tighten both inside adapter screws.

1. Insert lock body into mortised cutout (Fig. 3A).

Connector and wires must be coiled within

retaining ring in cylinder hole.

2. Push cable and connector through

perforated

sticker* on non-cylinder side of hole.

*

Note: If hand of lock body has changed, sticker will

have been removed (see previous 2).

3. Hold lock body loosely in place with (2) lock

body screws.

(2) #12-24 x 1/2”

Flat Head Screws

(Metal Doors)

(2) #12 x 1-1/4”

Flat Head Screws

(Metal Doors)

Note: Do not completely tighten

screws at this time.

4 - Installation of Outside & Inside

Lever Assembly Lock Body

Mortise Lock Body

Connector and Ground Ring

Terminal

Inside Adapter Plate

Rose

Set Screw

Outside Lever

Assembly

9

A7807C

Copyright © 2012, Sargent Manufacturing Company

, an ASSA ABLOY Group company

. All rights reser

ved.

Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.

10/31/12

Passport 1000 PG Mortise Lock

Advertising