• SofLink

Plus applications software must be used with (G1-PA & G1-TA) controller for programming

• The Master Code is

always User “01”. The Master Code assigns the Emergency and Supervisory Codes.

It is also used for programming. Users are deleted through the Master Programming Code only

• Emergency code is a 10 second unlock time and will override a thrown deadbolt on a mortise lock

• Emergency Code is at User number (location) “02”

The Supervisory Code is at User number “03”

• The Supervisory Code allows temporary lock out of selected users, changes duration of unlock time, requests

infrared interrogation output, and may add additional User Codes

• The User Codes are entered at user number “04” or higher. User numbers do not have to be used or entered

sequentially

Note: All User Codes must be followed by an asterisk ( * ).

• The “Lock Out” user is location dependent - all users above the chosen user number location are locked out of

the keypad. To ensure that all users except Master, Emergency and Supervisor are locked out, program this
user at user number location “04”.

To Begin Programming:

The Lock Controller is preset at the factory with Master Code 1234.
Entering 1234 * will unlock the lock allowing the lever handle to retract the latchbolt.

Note: The Master Code must be changed (i.e., "Forced Change") prior to adding users.

Initial Set-Up Procedures

• The following are typical procedures to be used when setting up your Profile Series LK lock:

• If a mistake is made during any of the procedures, depress the “*” key several times until the yellow LED goes out

• If no keystroke is made in a 30 sec. timeframe, the programming up to that point will default and you will have

to start over

The LK Keypad Lock can support 100 users.
Each user is assigned a User Number in addition to the code used for entry.

Keypad Programming Instructions for the Profile Series LK