Lk programming (100 users), Change the master code, Enter a user code – SARGENT Profile Series Cylindrical Locks User Manual

Page 4: Enter a passage (maintained) code, Enter a lock out user code

Advertising
background image

C

o

p

yr

ig

h

t

©

S

A

R

G

EN

T

M

a

n

u

fa

c

tu

ri

n

g

.A

ll

ri

g

h

ts

re

se

rv

e

d

.

R

e

p

ro

d

u

c

ti

o

n

in

w

h

o

le

o

r

in

p

a

rt

w

it

h

o

u

t

th

e

e

xp

re

ss

w

ri

tt

e

n

p

e

rm

is

si

o

n

o

f

S

A

R

G

EN

T

M

a

n

u

fa

c

tu

ri

n

g

is

p

ro

h

ib

it

e

d

.

2

800-810-WIRE (9473) • www.sargentlock.com • A7857A

Keypad Programming Instructions for the Profile Series LK Lock

LK Programming (100 Users)

To determine programming steps for your lock:

• If your controller has an LK label,, use the programming below.
• If your controller has a "G1.5" label and a keypad, refer to Section 3;
• If your controller has a "G1.5" label and no keypad refer to Section 4.

• If your label has a G1-LU, G1-PK, G1-PA, G1-TU, G1-TP or G1-TA; refer to

Keypad Programming Instructions A7716 at www.sargentlock.com

Change the Master Code

99# 1234*

Yellow LED blinks

50# 1#

Yellow LED blinks

New Master Code*

Yellow LED blinks quickly

New Master Code*

Yellow LED blinks slowly

*

Yellow LED goes out (If solid, see note)

This example uses the Factory Default 1234*
It is recommended not to use the factory default master code.

To Enter the Emergency Code

99# Master Code*

Yellow LED blinks

50# 02#

Yellow LED blinks

Emergency (1-6 digits)*

Yellow LED blinks quickly

Emergency (1-6 digits)*

Yellow LED blinks slowly (If solid, see note)

*

Yellow LED goes out

Emergency Code defaults to a 10 second unlock time and will override a thrown deadbolt on a mortise lock.

To Enter or Change the Supervisor Code

99# Master Code*

Yellow LED blinks

50# 1# 03#

Yellow LED blinks

Supervisory (1-6 digits)*

Yellow LED blinks quickly

Supervisory (1-6 digits)*

Yellow LED blinks slowly (If solid, see note)

*

Yellow LED goes out

Enter A User Code

99# Master Code* or Supervisory Code*

Yellow LED blinks

50# 1# (User Number 04-100)#

Yellow LED blinks

User Code (1-6 digits)*

Yellow LED blinks quickly

User Code (1-6 digits)*

Yellow LED blinks slowly (If solid, see note)

*

Yellow LED goes out

Enter A Passage (Maintained) Code

99# Master Code*

Yellow LED blinks

50# 0# (User Number 04-100)#

Yellow LED blinks

User Code (1-6 digits)*

Yellow LED blinks quickly

User Code (1-6 digits)*

Yellow LED blinks slowly (If solid, see note)

*

Yellow LED goes out

Enter a Lock Out User Code

99# Master Code*

Yellow LED blinks

50# 3# (User Number 04-100)#

Yellow LED blinks

User Code*

Yellow LED blinks quickly

User Code*

Yellow LED blinks slowly (If solid, see note)

*

Yellow LED goes out

The “Lock Out” user is location dependent — all users above the chosen user number location are locked out of the
keypad. To ensure that all users except Master, Supervisor and Emergency are locked out, program this user at
user number location “04”.

-

+

-

+

-

+

-

+

+

-

+

-

LK

1

Advertising