SARGENT Profile Series Cylindrical Locks User Manual

Page 2

Advertising
background image

Table of Contents

General Description

Installation of RF Technology Lock .......................1

How to Enter Preamble and RF User Codes .............2

Keypad Programming .......................................3

Additional Keypad Programming ..........................4

Appendix ......................................................5

Supplemental RF Technology Door Log Sheet ..........6

1

2

3

4

5

6

7

Page

For installation assistance, contact SARGENT at 800-810-WIRE (9473)

General Description

1

The RF Technology lock (TU & TP Prefixes) operates similar to other Profile Series locks with the added option of
remote wireless actuation. These Users are specified through the application software (SofLink Plus™) or
keypad programming of the lock. To activate the RF Technology lock remotely requires the use of a hand held
RF transmitter called an RF Fob.

To use an RF Fob for remote activation of the lock, the RF receiver must be configured with a 3-digit (100-999)
preamble code. This (user selectable) preamble code ensures that an RF Fob from another facility cannot
actuate the RF lock.

Note: The preamble code can only be entered directly into the RF receiver via the keypad.

A RF Technology lock is shipped with the default preamble code of 649 from the factory. It is strongly
recommended that the default preamble code
be changed in the field.

For additional default settings, see the Supplemental RF Technology Door Log Sheet, table 1, page 6.

After the RF receiver is configured with the selected preamble code, the controller board must be programmed
with the complete RF User Code. The RF User Code is 6-digits and can be entered through the application
software (SofLink Plus) or the keypad. The first 3-digits of the RF User Code are the preamble code, while the
second 3-digits are the RF Fob code. The RF Fob code is marked on the printed label of the RF Fob.

Panic user codes can only be entered into the lock via the keypad and must be re-entered after any
SofLink Plus download. They cannot be entered using SofLink Plus application software.