Keypad programming 4 – SARGENT Profile Series Cylindrical Locks User Manual

Page 5

Advertising
background image

3

For installation assistance, contact SARGENT at 800-810-WIRE (9473)

Keypad Programming

4

To Change the RF Program Code:

Press (up to 3 seconds) the # sign on the keypad until you hear 3 beeps and the yellow LED blinks continually.
(RF Receiver is now in program mode)

Note: The factory default RF Program Code is 6798. It is recommended that this code be changed in the field.

RF Program Code

#

Yellow LED double blinks

901

#

Yellow LED double blinks

New Program Code (1-6 digit)

#

Yellow LED double blinks

New Program Code (1-6 digit)

#

Yellow LED double blinks

#

5 Beeps & Yellow LED goes out

To Change the 3 digit (100-999) Preamble Code:

Press (up to 3 seconds) the # sign on the keypad until you hear 3 beeps and the yellow LED blinks continually.
(RF Receiver is now in program mode)

Note: The RF Technology lock is provided with a factory default preamble code of 649. It is recommended that
this default preamble code be changed in the field.

RF Program Code

#

Yellow LED double blinks

975

#

Yellow LED double blinks

(New 3 digit preamble code)

#

Yellow LED double blinks

(New 3 digit preamble code)

#

3 Beeps & Yellow LED double blinks

#

5 Beeps & Yellow LED goes out

To Program a Panic User :

99#1234

*

Yellow LED blinks

50

#

9

#

Yellow LED blinks

User Number (04-500)

#

Yellow LED blinks

RF User Code

*

Yellow LED blinks faster

RF User Code

*

Yellow LED blinks slower

*

Yellow LED goes out

To Program a Standard User :

99

#

1234

*

Yellow LED blinks

50

#

1

#

Yellow LED blinks

User Number (04-500)

#

Yellow LED blinks

RF User Code

*

Yellow LED blinks faster

RF User Code

*

Yellow LED blinks slower

*

Yellow LED goes out

To Program a Passage User :

99

#

1234

*

Yellow LED blinks

50

#

0

#

Yellow LED blinks

User Number (04-500)

#

Yellow LED blinks

RF User Code

*

Yellow LED blinks faster

RF User Code

*

Yellow LED blinks slower

*

Yellow LED goes out

Note: When programming the controller board with SofLink Plus software specify the User Type and enter
the 6-digit RF User Code in the Code section of the User Data screen; then download information to the
lock. Panic user codes can only be entered into the lock via the keypad and must be re-entered after any
SofLink Plus download. They cannot be entered using SofLink Plus application software.

Advertising