1

For installation assistance, contact SARGENT at 800-810-WIRE (9473)

Installation of the RF Technology Lock

2

Refer to the appropriate Profile Series Instruction Manual and templates for the door prep and installation
of the RF Technology Lock with exception of the following:

• Installation of the top thru-bolt screw
• Removal process for the battery keeper

The antenna board must be carefully moved to access the upper thru-bolt screw. Care should be taken
to prevent damage to the antenna retaining tabs during this process.

Press the two tabs away from the antenna board and lift the board off the mounting posts. Insert the flat head
thru-bolt and secure the escutcheon in place. After tightening the top thru-bolt, replace the antenna board by
placing it on the mounting posts and pressing into the retaining tabs.

A. Installation of the top thru-bolt screw:

To remove the battery keeper, a flat bladed screwdriver or similar tool must be used.

Insert the screwdriver into the slot at the top of the battery keeper, lift up and pull the top of the keeper
away from the batteries.

To install, insert the tabs on the bottom of the keeper into the battery compartment slots and press the
keeper tightly against batteries.

B. Removal procedure for the Battery Keeper:

Flathead thru-bolt

Antenna

Board

Retaining

Tabs

Mounting

Posts

Controller

Assembly

Insert screwdriver
tip and lift up

Battery
Keeper

Tip out

Keeper tabs

Replacement Parts Description

RF Technology Component

Part Number

RF Keypad Assembly

52-2546

RF Controller Assembly (TU)

52-2527

RF Controller Assembly (TP)

52-2534