RF Technology Lock Notes:

Low battery indication via 6 beeps after a valid RF Fob is depressed

Passage mode indication via 6 beeps upon unlocking

Passage mode unlocked condition has precedence over other users

Panic indication via 1 long beep followed by 5 short beeps

Panic mode reset by entering Master or Emergency code (at keypad only)

Disabled RF Receiver provides 5 beeps after valid RF Fob is depressed

If lock does not actuate after 3 seconds depress RF Fob again

Glossary of Terms

RF Technology:

A Profile Series option to remotely actuate a lock using a wireless hand held transmitter
referred to as the RF Fob.

RF Receiver:

A circuit board (located under battery cover) that recognizes the signal emitted from
an RF Fob.

RF Program Code:

The equivalent of a master code for the RF Receiver. The RF Program code is
necessary to make program changes such as the preamble code and the red LED
indicator light time duration.

Preamble Code:

A 3-digit number (field selectable) required for enhancing the security of the RF Technology
lock. This code must be entered through the keypad. The preamble code represents
the first 3-digits of the RF User Code.

Controller Board:

The circuit board located behind the battery compartment in the inside escutcheon. The
RF User Codes are programmed and stored in this board with the keypad or
SofLink Plus™ software.

RF Fob Code:

A 3-digit number that is labeled on the RF Fob representing the last 3 digits of the RF
User Code.

RF User Code:

A 6-digit number that operates the RF Technology lock.

RF User Code = Preamble Code + RF Fob Code

Command Number:

A 3-digit number that the RF Receiver recognizes to perform specific programming
functions. For example, the command number to program the preamble code into the
receiver is 975.

User Types:

The RF Technology lock can be programmed to remotely actuate in different ways.
These are referred to as User Types: Panic, Passage and Standard.

Panic User:

An RF Fob specified as this type of User will remotely lock the outside lever. Must be
programmed via the keypad and re-enter after any SofLink Plus user download.
A Master or Emergency level User code is required to remove the lock from
this condition.

Passage User:

An RF Fob configured as this type of User will remotely toggle (lock and unlock) the lock.

Standard User:

An RF Fob configured as this type of User will remotely unlock the lock for a defined
period of time (1-99 seconds). After which the lock will relock itself.