Mortise installation instructions (continued), Step #3 – apply fire stop plate (required for 12-), Profile series exit device – SARGENT Profile Series Exit Devices User Manual
Page 12

10
800-810-WIRE (9473) • www.sargentlock.com • A7455B
Profile Series Exit Device
Copyright © 2003, 2008, Sargent Manufacturing Company
, an A
SSA ABL
O
Y
Group company
. All rights reserved.
Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
Step #3 – Apply Fire Stop Plate (Required for 12-)
Inside of
door
Outside of
door
CL OF 1-1/2" Dia.
(2) Self tapping
screws #8 x 1/2"
long for wood &
metal doors
(2) 1/8" Dia. holes can
be drilled if the door is
not supplied with them
Slot
1-1/2'' Dia.
1-1/2''
7/8''
NOTE: Fire stop plate is required
on all fire rated doors
1. Fire stop plate for 12-devices
• Fire stop plate required in all fire rated doors (12-)
• Drill (2) 1/8" diameter holes if the door is not supplied with them
• Secure fire stop plate to door with (2) #8 x 1/2" self tapping screws