Step #3 – Apply Fire Stop Plate (Required for 12-)

Inside of

door

Outside of

door

CL OF 1-1/2" Dia.

(2) Self tapping
screws #8 x 1/2"
long for wood &
metal doors

(2) 1/8" Dia. holes can
be drilled if the door is
not supplied with them

Slot

1-1/2'' Dia.

1-1/2''

7/8''

NOTE: Fire stop plate is required

on all fire rated doors

1. Fire stop plate for 12-devices

• Fire stop plate required in all fire rated doors (12-)

• Drill (2) 1/8" diameter holes if the door is not supplied with them

• Secure fire stop plate to door with (2) #8 x 1/2" self tapping screws

Mortise Installation Instructions (Continued)