Reprogramming
1. With Card selected as a "CommEnable" User Type programmed with SofLink Plus

Software. When this is done, presenting the "CommEnable" prox card to the lock will
allow the unit to wake up and initiate the communications channel to the PC without the
need to press the CommEnable push button. Follow "First Time Programming" procedure,
except skip step 5.

2. With Card previously programmed (other than CommEnable User Type). Follow

"First Time Programming" procedure.

First Time Programming
(Using any HID Card and the PA controller
Comm Enable push button)
Note: Card can also be a Fob or Prox Tag

1. Create / Open Door File for PA Lock

2. Connect lock to PC (or PDP) using

connectors and cable

3. On PC - Click "Send to Door"

On PDP – Click "Up/Down"

4. Wake up the PA lock by presenting a HID

Card at the PA prox assembly.

5. Within a couple seconds press and hold the

PA controller Comm Enable push button for
2 seconds, then release the button

6. On PC or PDP, click “OK”

7. Click OK. If there was an error, check

connections and repeat process starting at
Step 2.

8. *The Card will NOT signal the lock for 45

seconds from the start of the downloading
process. After this time expires, the card
should function as indicated by its User
Type.

Message appears on PC "Please
enter your communication code at
the controller and then click OK."
Do NOT click OK at this point

PA prox assembly - Green LED
flashes and lock beeps several
times

The PC or PDP starts transfering
the door file to the PA lock. When
finished, PC Displays "Transfer
Complete"